| Universal SMD Form & Trim Systems Specifications |
- Shoulder dimension (B) minimum is determined with an easily removable insert.
- Lead material thickness maximum (C) and (G) are accommodated with the same
removable insert for consistent forms. - Standoff (A) is controlled with a built-in, 1:1 ratio, maintenance free micrometer.
- Lead exit point (D) is a maximum of .150", or a total body thickness of .300".
- Foot length (X) is infinitely variable on the F-1B/3A.
- Heel radius (H) is determined by the easily interchangeable upper former.
- Optional 4" tools meet similar features & specifications.